7
■
Check with a qualified electrician if you are not sure the
washer is properly grounded.
■
Do not have a fuse in the neutral or ground circuit.
INSTALLATION
INSTRUCTIONS
Remove Transport System
IMPORTANT:
Position the washer so that the rear of the unit is
within approximately 3 ft (90 cm) of the final location.
There are 4 bolts in the rear panel of the washer that support the
suspension system during transportation.
1.
Using a 13 mm wrench, loosen each of the bolts.
2.
Once the bolt is loose, move it to the center of the hole and
completely pull out the bolt, including the plastic spacer
covering the bolt and the cable attached to the bolt. The
power cord will be attached to all 4 bolts.
3.
Once all 4 bolts are removed, remove the power cord from
each bolt holder, and discard bolts, plastic spacers, and
cables.
4.
Close the holes with the transport bolt hole plugs.
1. 3 prong grounding plug
2. 3 prong grounding-type wall receptacle
3. Grounding prong
4. Power supply cord
1
2
3
4
GROUNDING INSTRUCTIONS
For a grounded, cord-connected washer:
This washer must be grounded. In the event of a mal-
function or breakdown, grounding will reduce the risk
of electrical shock by providing a path of least resist-
ance for electric current. This washer is equipped with
a cord having an equipment-grounding conductor and
a grounding plug. The plug must be plugged into an
appropriate outlet that is properly installed and ground-
ed in accordance with all local codes and ordinances.
WARNING: Improper connection of the equipment-
grounding conductor can result in a risk of electric
shock. Check with a qualified electrician or serviceman
if you are in doubt as to whether the appliance is prop-
erly grounded.
Do not modify the plug provided with the appliance –
if it will not fit the outlet, have a proper outlet installed
by a qualified electrician.
For a permanently connected washer:
This washer must be connected to a grounded metal,
permanent wiring system, or an equipment grounding
conductor must be run with the circuit conductors and
connected to the equipment-grounding terminal or lead
on the appliance.
WARNING
Excessive Weight Hazard
Use two or more people to move and install
washer.
Failure to do so can result in back or other injury.
HOT COLD