Whirlpool 3397616 Washer/Dryer User Manual


 
Panel G
Recessed and closet
installation instructions
This washer/dryer may be installed in a
recessed area or closet.
The installation spacing is in inches and
is minimum allowable. Additional
spacing should be considered for ease
of installation, servicing and compliance
with local codes and ordinances.
If closet door is installed, the minimum
unobstructed air openings in top and
bottom are required. Louvered doors
with equivalent air openings are
acceptable. Closet installation must be
exhausted.
Other installations must use the minimum
dimensions indicated.
Recessed, non-exhausted installation must use only the
rear exhaust position and Exhaust Deflector Part No. 694609.
Note: If recessed installation is exhausted to the side or rear,
6" must be available above the washer/dryer but all other
spacing can be 0".
Product dimensions
*Additional clearances for wall, door and floor moldings may be required or if external exhaust
elbow is used.
**Opening is minimum for closet door. Louvered door with equivalent air openings is acceptable.
***Additional space may be needed for exhaust elbow.
6"
0" ***
dryer
washer
Closet installation must be exhausted outdoors.
closet door
side view
48 sq. in. **
24 sq. in. **
6"
1" min.
3"
3"
48 sq. in. **
front view
side view
closet door
Recessed area minimum
installation spacing
72-3/4"
5"
33-1/4"
32-1/4"
side view
24 sq. in. **
34-3/4"
28"
26-1/4"
0" *
0" *
front view
48"
rear view
27-3/8"
13-11/16"
13-11/16"
1-1/2"
hot
water
inlet
13-1/2"
recess width
5"
recess
depth
27"
cold
water
inlet
exhaust
outlet
36-3/4"
28-1/2"
drain
outlet
22-3/4"
0" *
WARNING - To reduce the risk of fire, this appliance MUST BE EXHAUSTED OUTDOORS.
Most installation will require at least 5 inch
clearance behind the dryer for the dryer vent.
Location must be large enough to fully open dryer
door.
SURE CONNECT
TM
Vent Kit
CRUSH
RESISTANT
Dura Safe
TM
Kits Make Installation Easy
Provides 4 1/2”
clearance between
dryer and wall
Snap-Lock fittings
Total kit length
8 feet
Additional vent can
be snapped between
sections for
longer runs
Kit Contains:
2- 4' vent sections with attached close elbows
1- Wall plate for close clearance installations
2- 4" clamps
Part #4396028
Sections separate,
fittings can face
same or opposite
Extra long
band-clamp
for dryer
connection
Swivel collar
Beveled edges
allow corner
installations
Telescoping
sections
Swivel collar
wall connection
Provides 2 1/2” clearance
between dryer and wall
Great for closet
installations
0"-18", 18”-29” or
29”- 50” periscopes
include one male
snap-lock fitting,
one extra long
draw-band collar
and one clamp
2
1/ 2 "
2
1
/
2
"
Periscopes For Offset
Outlets, Tight Installations
Use when vent outlets
overlap or are offset
Excess length can
be trimmed to fit
18"-29" and 29"-50" Periscope
0"-18" Periscope
0"-18" : Part #4396037
18"-29" : Part #4396011
29"-50" : Part #4396014
Part #4396037
18"-29" : Part #4396011 29"-50" : Part #4396014
Dura Safe and Sure Connect are Trademarks of Whirlpool, U.S.A.