Sterling SDAP Clothes Dryer User Manual


 
SDAP Nomad Dryer with AP1 Control
Reference Manual (PN: 882.00281.00) for
Complete Operation and Installation Instructions
(Available online at www.sterlco.com)
Sterling Part No: 682.92636.03
2900 S. 160
th
Street • New Berlin, WI 53151 USA Bulletin No: DH1-315.02
Tel. 262.641.8610 • Fax 262.641.8653
Maintenance
Cooling Coils: Cleaning and Replacement Procedures
1. Shut down the dryer, tag out and lock out the controls if
necessary.
2. Shut the water off to the cooling coil.
3. Remove the four 10-32 bolts.
4. Gently slide the cooling coil out.
5. Visually inspect the coil for leaks, dirt, and any sign of
contaminants.
6. Blow the dust out, or if the coil is covered with plasticizer,
steam clean it.
7. Place the coil back in its housing. Make sure the gasket is
undamaged; replace if necessary.
8. Inset the four 10-32 bolts back in place.
9. Turn the water to the cooling coil back on.
(Return Air Filter)
Filters: Recommendations for Cleaning and Replacing
1. Turn off and/or lock out electrical power to the dryer.
2. Loosen the clamp, and remove the dust can.
3. Remove the thumb nut, on the center retaining rod, to remove the
filter cartridge.
4. Pull the filter cartridge out.
Vacuuming
Try vacuum-cleaning a soiled filter first. Vacuuming removes most
large particles and surface contaminants, and may suffice for the first
time you clean a filter.
Use a commercial-duty (recommended) or household vacuum
cleaner. Vacuum the filter from the air intake (dirty) side only.
Cleaning with Compressed Air
1. Blow clean, dry, compressed air up and down the pleats, blowing out
the filter from the inside out.
2. Remove loose dirt from the filter with compressed air or vacuum from
the outside.
3. Inspect the filter element. Briefly hold a light bulb behind the element
and look for any fatigued paper or residual dirt. Inspect for holes and
tears by looking though the filter toward a bright light. Check for
damaged gaskets or dented metal parts.
Note: Do not re-use a damaged filter!
Thumb Nut
Clamp
Dust Can
Filter
Cartridge
Filter Housing
Air In
Air Out
(Cooling Coil)
Undo (4) 10-32 Button
Head Screws using 1/8
Allen Wrench
Use compressed air or a steam
cleaner to blow the dust off or
clean any oily residue on the coil.
1" Wide x 1/8" Thick High
Temperature Gasket
Water flow requirement:
If used as an After-Cooler: 3 to 4 GPM @80°F.
If used as a Plasticizer Trap: 3 to 4 GPM @ 40°F to
45°F.
(Air Flow Schematic)
Process
Heater
Desiccant
Tanks
Filter
Blower
Valve
T’Couple
Location
Slide
Gate
ON
O
F
F
M1
DH
M1
HB
Hopper
Blower
MB
Machine
Blower
Drying Hopper
Loader
Machine 1
Loader
Machine 2
Loader
Convey to Drying Hopper With
Proportioning Valve & Two
Machines, Configuration “DP”
Convey to Drying Hopper With
Proportioning Valve & Two
Machines, Configuration “CP”