Speed Queen TMB1268C Clothes Dryer User Manual


 
© Published by permission of the copyright owner – DO NOT COPY or TRANSMIT
Installation/Operation Supplement
M414881 (EN)
20
120 Pound Tumblers
Figure 3
TMB2014N
NOTE: Refer to Table 3 for sizing of steam lines. Piping must also be sized accordingly for length of runs and number
of elbows.
1 Supply 8 457 mm (18 in.) Drop
2 305 mm (12 in.) Riser 9 Solenoid Valve (Supplied with machine)
3 Shut-Off Valve 10 Steam Bonnet
4 Condensate Return Line from Supply Line 11 Flexible Line
5 Return 12 Union
6 Check Valve 13 Trap with Built-in Strainer
7 Vacuum Breaker (optional)
Model
Steam Pressure
bar (PSI)
Minimum Pipe Diameter
Steam Trap Size*
(Pounds Condensate/Hour)
120S
8.3 - 8.6 (120-125) 1 in. NPT 345
4.1 - 8.3 (60-120) 1 in. NPT 345
2.4 - 4.1 (35-60) 1-1/4 in. NPT 345
*Based on maximum PSI.
Table 3
TMB2014N
2
12
6
3
5
1
13
10
9
8
6
7
4
11