Installing the Dryer
Step 1: Position and Level the Dryer
Install dryer before washer. This allows room for
attaching exhaust duct.
Select a location with a solid floor. Dryers installed in
residential garages must be elevated 18 inches (46 cm)
above the floor.
No other fuel burning appliance should be installed in
the same closet with the dryer.
The dryer must not be installed or stored in an area
where it will be exposed to water and/or weather.
The dryers needs sufficient clearance and an adequate
air supply for proper operation and ventilation, and for
easier installation and servicing. (Minimum clearances
are shown below).
Figure 2
D823I
1 Closet Door
2 Centered Air Openings (G) (2 Openings
minimum)
3 Outer Wall of Enclosure
**NOTE: For new installations, locate top of wall vent 42 inches (106.7 cm) above floor to make venting
easier to connect.
1
2 (G)
3
A
E
**42 in.
(106.7 cm)
F
F
B
A
A
C
FRONT VIEW
(w/o Closet Door)
SIDE VIEW
(Closet Door)
FRONT VIEW
(Closet Door)
D
Area Description
Free Standing/Alcove
Installation
Closet Installation
A Dryer sides and rear clearance 0 in. (0 cm) 0 in. (0 cm)
B Dryer top clearance 12 in. (30.5 cm) 12 in. (30.5 cm)
C Dryer front clearance Not Applicable 2 in. (5.1 cm)
D Exhaust duct clearance to
combustible material
2 in. (5.1 cm) 2 in. (5.1 cm)
E Weather hood to ground clearance 12 in. (30.5 cm) 12 in. (30.5 cm)
F Distance from floor or ceiling to
hole edge
Not Applicable 3 in. (7.6 cm)
G* Area of centered air openings in
closet door
Not Applicable 40 sq. in./open (260 sq. cm)
*Louvered door with equivalent air openings is acceptable. (Minimum clearances are shown.)