Grounding Information
The dryer must be grounded. In the event of
malfunction or breakdown, grounding will reduce the
risk of electric shock by providing a path of least
resistance for electric current. The dryer is equipped
with a cord having an equipment-grounding conductor
and a 3 prong grounding plug. The three-prong
grounding plug on the power cord should be plugged
directly into a polarized three-slot effectively
grounded receptacle rated 110/120 Volts AC
(alternating current) 15 Amps.
Do not modify the plug provided with the dryer – if it
will not fit the outlet, have a proper outlet installed by
a qualified electrician.
NOTE: Have a qualified electrician check the
polarity of the wall receptacle. If a voltage reading
is measured other than that illustrated, the
qualified electrician should correct the problem.
Do not operate other appliances on the same circuit
when this appliance is operating.
Step 8: Recheck Steps 1-7
Refer to Installer Checklist on the back cover of this
manual and make sure that dryer is installed correctly.
Step 9: Check Heat Source
Electric Dryers
Close the loading door and start the dryer in a heat
setting (refer to the Operating Instructions supplied
with the dryer). After the dryer has operated for three
minutes, the exhaust air or exhaust pipe should be
warm.
This dryer is equipped with a three-prong
(grounding) plug for your protection
against shock hazard and should be
plugged directly into a properly grounded
three-prong receptacle. Do not cut or
remove the grounding prong from this plug.
W036
WARNING
Improper connection of the equipment-
grounding conductor can result in a risk of
electric shock. Check with a qualified
electrician or service person if you are in
doubt as to whether the dryer is properly
grounded.
W038
WARNING
To reduce the risk of an electric shock or
fire, DO NOT use an extension cord or an
adapter to connect the dryer to the electrical
power source.
W037
WARNING
DRY2022N
1 “L1”
2 Ground
3 Neutral
4 Neutral SIde
5 Round Grounding Prong
Figure 17
D254I
DRY2
0 V.A.C
120±12
V.A.C
Plug cord into separately fused 15 Amp circuit.
3
2
1
4
5
120±12
V.A.C