129316
Strictly switch the appliance off prior
cleaning (unplug the power cord from the
wall socket, or turn the selector jog to the
position
“0”).
•
Clean the casing and drum interior with soft cloth
and mild detergent.
•
Periodically clean (vacuum) the interior of air
evacuation opening and evacuation tube.
Water condensation device should be cleaned
three to four times a year, in case of very frequent
use even more often.
During cleaning a certain amount of water may
drip out so it is good to put an absorbing cloth
below the opening.
•
Open the exterior lid of the condenser by grabbing
the handle on the lower left part of the appliance
housing and pull it downwards.
•
Remove the interior lid by fi rst turning the lever
vertically down, then tilt the lid towards yourself
and remove it.
•
Turn the lock on the condenser upwards and pull
the condenser out by pulling the lever.
•
Clean the device from both sides with lukewarm
water and drain it well.
•
Before replacing it into its slot, clean the air
channel in which the device is mounted, and the
gasket at the interior lid.
•
Lock the condenser into its place.
•
Insert the inner lid to seal well and lock it with a
handle.
•
Push the exterior lid towards the appliance to lock
to its place.
17
Cleaning the water
condensation device
Cleaning of evacuation
drier