Samsung DV4015J Clothes Dryer User Manual


 
EXHAUST LENGTH CALCULATION
Table 1: RECOMMENDED MAXIMUM LENGTH
* Do not use non metallic flexible duct.
EXHAUST DIRECTIONS
All dryers shipped from the factory are set up for rear exhausting. However exhausting
can be on the right or left side of the cabinet or the bottom of the dryer.
Remove access panel at back of dryer to gain access to internal ducts.
Disconnect duct exhaust from blower housing.
Remove desired knockout plate (either right or left side).
Attach a 90° elbow duct to blower housing and facing desired opening.
Reinstall rear access panel.
EXHAUST DUCT LOCATING DIMENSIONS
NOTE: Non-metallic ducts must never be used inside dryer cabinet.
SPECIAL ACCESSORY
Stacking kit(Model no:SK-2)
You can obtain the stacking kit from your retailer.
With this kit you can combine your dryer with Samsung
automatic washing machine to a washing and drying column.
The appliances are stacked in space-economizing manner in
this arrangement, the washing machine at the bottom and the
dryer at the top!
Installation Instructions
5
SAMSUNG Clothes Dryers Owner’s Instructions
ELECTRIC DRYERS
Weather Hood Type
Recommended Use only for short run installations
Rigid Metallic Flexible* Rigid Metallic Flexible*
14m(46ft.) 9m(30ft.) 11m(37ft.) 7m(24ft.)
11m(38ft.) 7.5m(25ft.) 9m(30ft.) 6m(20ft.)
9m(31ft.) 6m(20ft.) 6.5m(22ft.) 4m(14ft.)
7m(24ft.) 5m(16ft.) 4.5m(15ft.) 3m(10ft.)
No. of 90°
elbows
0
1
2
3
Same as
other side
3-3/4”
(9.5cm)
4-3/8”
(11cm)
3-3/4”
(9.5cm)
13-1/2”(34cm)
5-7/8”
(15cm)
Front of dryer
4”(10.16cm) 2 1/2”(6.35cm)