Samsung DV4006 Clothes Dryer User Manual


 
SPECIAL INSTALLATION REQUIREMENTS
ALCOVE OR CLOSET INSTALLATION
WARNING: To reduce the risk of fire, this dryer MUSTBE EXHAUSTED TO THE
OUTDOORS. See EXHAUST INFORMATION section.
Minimum clearances between dryer cabinet and adjacent walls or other surfaces are:
0” either side 1” front and rear
Minimum vertical space from floor to overhead cabinets, ceilings, etc. is 52”(132cm).
Closet door must be louvered or otherwise ventilated and must contain a minimum of
60 sq. in. of open area equally distributed. If this closet contains both a washer and a
dryer, doors must contain a minimum of 120 sq. in. of open area equally distributed.
MINIMUM CLEARANCES OTHER THAN ALCOVE OR CLOSET INSTALLATIONS.
Minimum clearances to combustible surfaces: 0 clearance both sides and 25 mm
(1”) rear.
MOBILE HOME INSTALLATION
The dryer must be exhausted to the outdoors with the termination securely fastened to the
mobile home structure. (See EXHAUST INFORMATION section.)
The exhaust MUST NOT be terminated beneath a mobile home.
Provisions must be made for the introduction of outside air into the dryer. The free air open-
ing shall not be less than 80 cm
2
(12 in
2
)
The exhaust duct material MUSTBE METAL.
The dryer must be attached to the floor following instructions available from the dealer.
Installation must comply with the current CAN/CSAZ240 MH series Mobile Home
Installation Codes.
NOTE: CONSIDERATION MUSTBE GIVEN TO INSTALLING AND SERVICING THE
APPLIANCE.
ELECTRICAL POWER SUPPLY
CAUTION: NEVER USE AN EXTENSION CORD WITH THIS APPLIANCE.
This dryer must be connected to an individual circuit identical to the one specified on the
rating plate of the loading port, protected by fuses or circuit breaker conforming to local
codes. THIS APPLIANCE MUST BE PROPERLY GROUNDED.
The power cord of this appliance is equipped with a three (3) or four (4) prong plug which
mates with an appropriate dryer wall receptacle.
GROUNDING INSTRUCTIONS
This appliance must be grounded. In the event of malfunction or breakdown, grounding will
reduce the risk of electric shock by providing a path of least resistance for electric current.
The plug must be plugged into an appropriate outlet that is properly installed and grounded
in accordance with all local codes and ordinances.
WARNING:
Improper connection of the equipment grounding conductor can result in a risk of electric
shock. Check with a qualified electrician or serviceman if you are in doubt as to whether the
appliance is properly grounded.
Do not modify the plug provided with the appliance - if it will not fit the outlet, have a
proper outlet installed by a qualified electrician.
Installation Instructions
6
SAMSUNG Clothes Dryers Owner’s Instructions