23
If you cannot make the cold water connection direct
from the rising mains, you may be able to operate the
appliance from your cold water storage system.
There should be a minimum distance of 5.02m
(16.5 ft) between the appliance’s inlet and the bottom of
the water storage tank.
Set the hoses correctly by loosening the ring nuts. After
positioning the inlet hoses, be sure to tighten the ring
nuts again to prevent leaks.
Water drainage
This appliance is designed to be permanently plumbed
into your home's drainage system using one of the
following methods.
1. Into a drainage standpipe.
Firstly form a hook in the end of the drain hose using
the “U” piece” supplied.
Place the drain hose into your standpipe, which should
have an internal diameter of approximately 38mm thus
ensuring there is an air break between the drain hose
and standpipe.
P1200
30 cm (12")
38 mm (11.2)
standpipe
diameter
U piece
supplied
P1199
P0021
P1088
When discharging into a standpipe ensure that the top of
the standpipe is no more than 90cm (35.4'') and no less
than 60cm (23.6'') above floor level.
The drain hose may be extended to a maximum of 4
metres. An additional drain hose and joining piece is
available from your local Service Force Centre.
The joining piece must have an internal diameter of
18mm.
If your drain hose looks like this (see below) you do not
require the “U” piece”. Just push the hose firmly into
the standpipe.
2. Onto a sink outlet spigot.
If the outlet spigot has not been used before, remove
any blanking plug that may be in place.
Push the drain hose onto the spigot and secure with a
clip if required, ensure a loop is formed in the drain
hose (see diagram) to prevent waste from the sink
entering the washing machine.
P1197
P1212
P1201
3 pin
Min. 60 cm (23.6)
Max. 90 cm (35.4)
132967680.qxd 31/10/2007 14.41 Pagina 23