Unpacking
All transit bolts and packing must be removed
before using the appliance.
You are advised to keep all the packaging for re-use in
case the machine is to be transported again.
Using a spanner unscrew and remove the rear right bolt.
Lay the machine gently on its back, making sure that the
hoses are not squashed.
Remove the polystyrene base and take off the bottom
panel by unscrewing the central screw. Carefully slide
out the right polythene bag.
Repeat the operation for the left and central polythene
bags.
Re-fit the bottom panel using the 4 screws supplied with
the door hinges (in the plastic bag) and the previously
removed screw.
P0453
P0016
P0015
P0457
P0255
Set the machine upright and remove the two remaining
bolts from the back.
Pull out the three plastic spacers from the holes into
which the bolts were fitted.
Plug the open holes with the plugs supplied with the
instruction booklet.
Positioning
Install the machine on a flat hard floor.
Make sure that air circulation around the machine is not
impeded by carpets, rugs etc. Check that the machine
does not touch the wall or other kitchen units.
Never place cardboard, wood or similar materials under
the machine to compensate for any unevenness in the
floor.
Your new washing machine has been designed to be
permanently plumbed in to your home’s water supply
and drainage system. However, if this is not possible, it
may be connected to a suitable existing tap with the
drain hose discharging into a sink.
The appliance has an inlet hose, with female 3/4” BSP
thread connector. If this connection is not compatible
with the plumbing of the existing installation, a variety
of connectors are available from good hardware stores
and plumbers merchants to suit most domestic
plumbing. Any alteration to your existing plumbing
must be carried out by a competent person, or qualified
plumber.
Water inlet
Connect the hose to a tap with a 3/4’’ thread.
Do not use previously employed hoses.
Installation should comply with local water authority
and building regulations’ requirements.
The appliance must be connected to a cold water
supply.
A minimum water pressure of 0.05 MPa (0.5 bar) is
required for safe operation of the appliance.