Make the electrical connection
GROUNDING INSTRUCTIONS
This appliance must be grounded. In
the event of malfunction or
breakdown, grounding will reduce
the risk of electric shock by
providing a path of least resistance
for electric current. This appliance is
equipped with a cord having an
equipment grounding conductor and
a grounding plug. The plug must be
plugged into an appropriate outlet
that is properly installed and
grounded in accordance with all
local codes and ordinances.
WARNING – Improper connection of
the equipment grounding conductor
can result in a risk of electric shock.
Check with a qualified electrician or
service representative or personnel
if you are in doubt as to whether the
appliance is properly grounded.
Do not modify the plug provided with
the appliance: if it will not fit the
outlet, have a proper outlet installed
by a qualified electrician.
Electrical connection
The dryer comes with a 5 ft long, 12/4
AWG cord and a NEMA 14-30 P plug.
It should be connected to a
120/208-240 V, 15 A, 60 Hz AC power
supply. A 3 pole-4 wire grounding
power outlet (NEMA type 14-30 R) is
necessary.
EASY INSTALLATION KIT
If you do not have a dedicated 15 Amp
line for this appliance, but you have the
standard, 120/208-240 V - 30 Amp,
60 Hz AC outlet, you can use the "Easy
Installation Kit", which allows you to use
that line to connect this appliance.
057B for on-site outlet NEMA 10-30 R
060B for on-site outlet NEMA 14-30 R
For more information on the "Easy
Installation Kit" or if you have questions
concerning the electrical connection
please contact:
USA 1-800-999-1360
techserv@mieleusa.com
CDN 1-800-565-6435
service@miele.ca
Installation
28