Maytag W10267633A Clothes Dryer User Manual


 
9
2. Place the hooked end of the neutral wire (white or center wire) of
direct wire cable under the center screw of terminal block (hook
facing right). Squeeze hooked end together. Tighten screw.
A
C
D
E
B
D. Neutral wire (white or center wire)
E.3/4" (19 mm) UL listed strain
relief
3. Place the hooked ends of the other direct wire cable wires under
the outer terminal block screws (hooks facing right). Squeeze
hooked ends together. Tighten screws.
4. Tighten strain relief screw.
5. Inser
t tab of terminal block cover into slot of dryer rear panel.
Secure cover with hold-down screw.
6. Y
ou have completed your electrical connection. Now go to
“Venting Requirements.”
Optional 3-wire connection
Use for direct wire or power supply cord where local codes do
not permit connecting cabinet-ground conductor to neutral wire.
1. Remove center
, silver-colored terminal block screw.
2. Remove neut
ral ground wire from external ground conductor
screw. Connect neutral ground wire and the neutral wire (white or
center wire) of power supply cord/cable under center, silver-
colored terminal block screw. Tighten screw.
A.External ground conductor
screw
B. Neutral ground wire
C. Center, silver-colored terminal
blo
ck screw
D. Neutral wire
(white or center wire)
E.3/4" (19 mm) UL listed
strain relief
F. Grounding path determined
by a quali
fied electrician
A
B
C
D
F
E
3. Connect the other wires to outer terminal block screws. Tighten
screws.
4. Tighten strain relief screws.
5. Insert tab of terminal block cover into slot of dryer rear panel.
Secure cover with hold-down screw.
6. Connect a separate copper ground wire from the external ground
conductor screw to an adequate ground.