Maytag MVW18CSAGW0 Washer/Dryer User Manual


 
17
ELECTRONIC CONTROLS SET-UP INSTRUCTIONS
Control Set-up Procedures
IMPORTANT: Read all instructions before operating.
The three key pads on the left side, the top key pad on the right
side, and the digital display are used to set up the controls. The
display can contain 4 numbers and/or letters and a decimal point.
These are used to indicate the set-up codes and related code
values available for use in programming the washer.
How to use the key pads to program the controls
1. The LEFT UPPER (POWER WASH) key pad is used to adjust
the values associated with set-up codes. Pressing the key
pad will increment the value.
Rapid adjustment is possible by holding the key pad down.
2. The LEFT MIDDLE (NORMAL) key pad will advance you
through the set-up codes. Pressing the key pad will advance
you to the next available set-up code. Holding the key pad
down will automatically advance through the set-up codes at
a rate of one (1) per second.
3. The LEFT LOWER (DELICATES) key pad is used to select or
deselect options.
4. The RIGHT UPPER (TEMPERATURE) key pad is used to
decrease set-up code value.
Start Operating Set-Up
n PD Models: Insert access door key, turn, and lift to remove
access door.
IMPORTANT: The console must not be opened unless power is
rst removed from the washer. To access connector AA1:
g
Unplug washer or disconnect power.
g
Open console, disconnect plug on AA1, close console.
g
Plug in washer or reconnect power.
The washer is now in the set-up mode.
Before proceeding, it is worth noting that, despite all of the
options available, an owner can simply choose to uncrate a new
commercial washer, hook it up, plug it in, and have a unit that
operates.
Set-up Codes
n The LEFT MIDDLE (NORMAL) key pad will advance from code
to code.
n The LEFT UPPER (POWER WASH) key pad will increase the
code value.
n The LEFT LOWER (DELICATES) key pad will select or
deselect options.
n The RIGHT UPPER (TEMPERATURE) key pad will decrease
the code value.
The set-up code is indicated by the one or two left-hand
characters. The set-up code value is indicated by the two
or three right-hand characters.
CODE EXPLANATION
6.06
NORMAL
NORMAL Regular Cycle Vend Price - Increase or decrease
between 0 and 200 by pressing the LEFT UPPER or RIGHT
UPPER key pad. Factory preset for 6 coins = $1.50.
6.04
DELICATES
DELICATES Regular Cycle Vend Price - Increase or decrease
between 0 and 200 by pressing the LEFT UPPER or RIGHT
UPPER key pad. Factory preset for 4 coins = $1.00.
6.08
POWERWASH
POWERWASH Regular Cycle Vend Price - Increase or decrease
between 0 and 200 by pressing the LEFT UPPER or RIGHT
UPPER key pad. Factory preset for 8 coins = $2.00.
g Press the LEFT MIDDLE key pad once to advance to next code.
7.00 ADDITIONAL WASH TIME
7.00 This is the number of minutes that can be added to a Wash Cycle.
Choose from 00-05 minutes by pressing the LEFT UPPER key
pad.
g Press the LEFT MIDDLE key pad once to advance to next code.
8.00 ADDITIONAL RINSE TIME
8.00 This is the number of minutes that can be added to a RINSE
Cycle. Choose from 00-05 minutes by pressing the LEFT UPPER
key pad.
NOTE: Additional rinse time only available in defaulted bath
rinses, not in spray rinse option.
g Press the LEFT MIDDLE key pad once to advance to next code.
9.00 CYCLE COUNTER OPTION
This option is either SELECTED ‘ON’ or NOT SELECTED ‘OFF’.
9.00 Not Selected ‘OFF’.
9.0C Selected ‘ON’ and not able to be deselected.
Press the LEFT LOWER key pad 3 consecutive times to select
‘ON’. Once selected ‘ON’ it cannot be deselected.
g Press the LEFT MIDDLE key pad once to advance to next code.
1.00 MONEY COUNTER OPTION
This option is either SELECTED ‘ON’ or NOT SELECTED ‘OFF’.
1.00 Not Selected ‘OFF’.
1.0C Selected ‘ON’.
Press the LEFT LOWER key pad 3 consecutive times to select
‘ON’ and 3 consecutive times to remove (Not Selected ‘OFF’.)
Counter resets by going from ‘OFF’ to ‘ON’.
1.C0 Selected ‘ON’ and not able to be deselected.
To select ‘ON’ and not able to be deselected, rst select ‘ON’,
then within two seconds press the LEFT LOWER key pad twice,
the LEFT UPPER key pad once, and exit the set-up mode.
g Press the LEFT MIDDLE key pad once to advance to next code.
2.00 SPECIAL PRICING OPTION
This option is either SELECTED ‘ON’ or NOT SELECTED ‘OFF’.
2.00 Not Selected ‘OFF’.
2.SP Selected ‘ON’. Press the LEFT LOWER key pad once for this
selection.
If SPECIAL PRICING OPTION is selected, there is access to codes ‘3.’
through ‘9.’.
NOTE: An external battery needs to be added to keep the clock running during
periods of power outages.
g Press the LEFT MIDDLE key pad once to advance to next code.