Maytag MDG75PNH Clothes Dryer User Manual


 
113394-7 Maytag Co. 19
2. Electrical Service Specifications
* AWG Stranded Wire Type...size wire as per National Electrical Code or local codes. 3/5/07
** 3-Wire is available.
NON-REVERSING (GAS)
ELEC TRICA L SERV ICE SPE CIFIC ATIONS (PER D RYER)
IMPORTANT:
NOTES
: A.
B.
C.
208 VAC AND 240 VAC ARE NOT THE SAME. When ordering, specify exact voltage.
When fuses are used they must be dual element, time delay, current limiting, class RK1 or RK5 ONLY.
Calculate/determine correct fuse value, by applying either local and/or National Electrical Codes
to listed appliance amp draw data.
Circuit breakers are thermal-magnetic (industrial) motor curve type ONLY. For others, calculate/verify
correct breaker size according to appliance amp draw rating and type of breaker used.
Circuit breakers for 3-phase (3Ø) dryers must be 3-pole type.
SERVICE
VOLTAGE
PHASE
WIRE
SERVICE
APPROX.
AMP DRAW
MINIMUM
WIRE SIZE
FUSING
CIRCUIT
BREAKER
Dual Element
Time Delay
60 Hz 50 Hz
120 2 13.0 * 20 20
208 2 7.6 * 15 15
220 2 7.3 8.6 * 15 15
230 2 8.0 * 15 15
240 2 7.0 * 15 15
208 3 4.7 * 15 15
230 3 4.7 * 15 15
240 3 4.9 * 15 15
380 3 2.9 * 15 15
380 4** 3.1 * 15 15
400 4** 3.2 * 15 15
416 4** 3.1 * 15 15
460/480 3 2.8 * 15 15
REVERSING (GAS)
ELEC TRICA L SERV ICE SPE CIFIC ATIONS (PE R D RYER)
IMPORTANT:
NOTES
: A.
B.
C.
208 VAC AND 240 VAC ARE NOT THE SAME. When ordering, specify exact voltage.
When fuses are used they must be dual element, time delay, current limiting, class RK1 or RK5 ONLY.
Calculate/determine correct fuse value, by applying either local and/or National Electrical Codes
to listed appliance amp draw data.
Circuit breakers are thermal-magnetic (industrial) type ONLY. For others, calculate/verify correct
breaker size according to appliance amp draw rating and type of breaker used.
Circuit breakers for 3-phase (3Ø) dryers must be 3-pole type.
SERVICE
VOLTAGE
PHASE
WIRE
SERVICE
APPROX.
AMP DRAW
MINIMUM
WIRE SIZE
FUSING
CIRCUIT
BREAKER
Dual Element
Time Delay
60 Hz 50 Hz
208 3 6.7 * 15 15
230 3 7.5 * 15 15
240 3 7.1 * 15 15
380 3 4.2 * 15 15
380 4** 4.3 * 15 15
400-416 4** 4.4 * 15 15
460/480 3 3.9 * 15 15
575 3 3.3 * 15 15
* AWG Stranded Wire Type...size wire as per National Electrical Code or local codes. 3/5/07
** 3-Wire is available.