Maytag MDG30PCC Washer/Dryer User Manual


 
35
2. For Models with Johnson Direct Spark Ignition (DSI) Controller (G760)
Theory of Operation:
Start the drying cycle. When the gas burner ignites within the
chosen trial for ignition time (6-seconds), the flame sensor detects
gas burner flame and signals the DSI module to keep the gas
valve open as long as there is a call for heat. The DSI module
will LOCK OUT if the gas burner flame
is not sensed at the
end of the trial for ignition period. The trial for ignition period
will
be repeated for a total of three (3) retries/trials (the initial try and
two [2] more retries/trials). If the flame
is not sensed at the end
of the third retry/trial (inter-purge period of 30-seconds) the DSI
module will LOCK OUT (light emitting diode [L.E.D.] diagnostic
indicator flashes).
A steady L.E.D. indicator indicates normal operation.
No L.E.D. indicator indicates a power or an internal failure has occurred.
3. For Models with Fenwal Controls DSI Module (128937)
Theory of Operation:
Start the drying cycle. When the gas burner ignites within the
chosen trial for ignition time (8-seconds), the flame sensor detects
gas burner flame and signals the DSI module to keep the gas
valve open as long as there is a call for heat. The DSI module
will LOCK OUT if the gas burner flame is not sensed at the
end of the trial for ignition period. The trial for ignition period will
be repeated for a total of three (3) retries/trials (the initial try and
two [2] more retries/trials). If the flame is not sensed at the end
of the third retry/trial (inter-purge period of 30-seconds), the DSI
module will LOCK OUT (a red L.E.D. diagnostic indicator will
flash).
An unlit red L.E.D. diagnostic indicator indicates normal operation.
A lit green L.E.D. diagnostic indicator indicates dryer controller is calling for heat and that ALL interlocks
have been satisfied.