Maytag MDG16PD Clothes Dryer User Manual


 
Page 8
7. COMMERCIAL INSTALLATION ACCESSORIES (continued)
Rectangular vent kit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 059144
Gas conversion kit NATURAL to LPG . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 306195
Gas conversion kit LPG to NATURAL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 306204
Additional earth bond connection wire . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 311155
Additional earth bond connection clamp . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 301548
8. FINAL CHECKLIST
Before leaving a completed installation, correct operation of the dryer must be checked:
Make sure all exhaust, gas, and electrical connections are correctly made
Make sure dryer is level and feet lock-nuts are tightened
Turn on gas supply (where applicable)
Switch on electricity supply
Following Operating Instructions, check the dryer operation
There are no installation adjustable parts on the gas components (except conversion kit). If the gas supply
pressure is correct, and these checks are satisfactory, the dryer should now be fully operational. If not, contact your
distributor for assistance.
On gas dryers the burner may not ignite initially due to air in the gas pipework. Allowing the dryer to operate on a
heat setting will purge the pipework. If the gas does not ignite within 5 minutes, turn the dryer off and wait for 5
more minutes. Make sure gas supply has been turned on. In order to confirm gas ignition and correct operation of
the burner (mostly blue flame) the professional installation engineer may remove the front panel and stacked pair
access panel to view the burner. WARNING Do not touch any electrical parts and replace panels immediately
after this check. To confirm gas ignition at any other time the exhaust duct should be checked for heat.
9. TECHNICAL SPECIFICATION (see dataplate by door opening for full model details)
Gas model:
220240V ~ 50 Hz 1ph 350W max. IP24 Clothes capacity: 9 kg max.
Gas Category: II
2H3+
Gross heat input: 6.5 kW (gas consumption 23.6 MJ/h)
Net Heat Input: 5.9 kW
Factory settings:
Natural gas: (G20) Gas rate: 0.62 m
3
/h (23.6 MJ/h) Injector size: 2.16mm
Supply pressure, normal: 20 mb (2 KPa) Test point pressure: 8.7 mb (0.87 KPa)
Supply pressure, min.: 11.3 mb (1.13 KPa) Test point pressure: 8.7 mb (0.87 KPa)
With LPG conversion kit (Europe):
LP gas: butane (G30) Gas rate: 0.19 m
3
/h (23.6 MJ/h) Injector size: 1.25mm
Supply pressure, normal: 29 mb (2.9 KPa) Test point pressure: Not applicable
LP gas: propane (G31) Gas rate: 0.246 m
3
/h (23.6 MJ/h) Injector size: 1.25mm
Supply pressure, normal: 37 mb (3.7 KPa) Test point pressure: Not applicable
With LPG conversion kit (Australia):
LP gas: propane (G31) Gas rate: 0.246 m
3
/h (23.6 MJ/h) Injector size: 1.35mm
Supply pressure, normal: 27.5 mb (2.75 KPa) Test point pressure: Not applicable
Countries of destination: UK, IE, IT, ES, AU
Electric model:
220240V ~ 50 Hz 1ph 4600W max. IP24 Clothes capacity: 9 kg max.