__ When connecting to the terminal block, place the hooked end of
3-wire connection: Power supply cord the wire under the screw of the terminal block (hook facing right),
squeeze hooked end together and tighten screw. See example
Use where local codes permit connecting cabinet-ground
conductor to neutral wire.
below.
24
; /
3 7 6
1.3-wire receptacle (NEMA type 10-3OR)
2. 3-wire plug
3. Neutral prong
4. Spade terminals with up turned ends
5. 3/4in. (!.9 cm) UL approved strain relief
6. Ring terminals
7. Neutral (white or center wire)
1. Loosen or remove center terminal block screw.
2. Connect neutral wire (white or center wire) of power supply
cord to the center, silver colored terminal screw of the
terminal block. Tighten screw.
2
1 -,,.,,%,
.........
"',,.,,4
1. Neutral wire (white or center wire)
2. Center sitver-cotored terminal block screw
3. Neutral grounding wire (green/yellow)
4. External ground connector
5. 3/4in. (!.9 cm) UL listed, strain relief
1. Loosen or remove center terminal block screw.
2. Placethehookedendoftheneutralwire(whiteorcenterwire)
of power supply cable under the center screw of terminal
block (hook facing right). Squeeze hooked end together.
Tighten screw.
,2
1. Neutral wire (white or center wire)
2. Center silver-colored terminal block screw
3. Neutral grounding wire (green/yellow)
4. External ground connector
5. _/4in. (!.9 em) UL listed, strain relief
3. Place the hooked ends of the other power supply cable wires
under the outer terminal block screws (hooks facing right).
Squeeze hooked ends together. Tighten screws.
3. Connect the other wires to outer terminal block screws.
Tighten screws.
4. Tighten strain relief screws.
5. Insert tab of terminal block cover into slot of dryer rear panel.
Secure cover with hold-down screw.
3-wire connection: Direct Wire
Use where local codes permit connecting cabinet-ground
conductor to neutral wire.
Direct wire cable must have 5 ft (1.52 m) of extra length so dryer
can be moved if needed.
Strip 3V2in. (8.9 cm) of outer covering from end of cable. Strip
insulation back 1 in. (2.5 cm) If using 3-wire cable with ground
wire, cut bare wire even with outer covering. Shape ends of wires
into a hook shape.
4. Tighten strain relief screws.
5. Insert tab of terminal block cover into slot of dryer rear panel.
Secure cover with hold-down screw.
11