if Electronic Laundry
Center does not start:
u Is plug disconnected from power
supply or is plug loose in outlet,
not making good connection?
• Is house fuse blown or circuit
breaker off?
o Is lid closed during spin cycle?
= Is dryer door closed?
o Have you touched START pad?
o The internal motor protector will
stop motor if it is overheated, but
will automatically reset after
motor cools.
if display window does not
indicate desired setting:
= Have correct Cycle, Options, and
Cycle Adjustments been selected?
o Has cycle setting accidentally
been reprogrammed?
See "Personalized Cycle" in Oper-
ating Instructions to return to
factory-set program or change per-
sonalized cycle.
If water does not enter:
• Are water valves turned on?
• Are filter screens clogged? They
are located at water valve ends of
hoses.
If there is no hot water:
o Are hot and cold water hoses
reversed? Hot water hose is iden-
tified.
If water does not drain:
o Are there kinks in drain hose?
o Is drain system clogged or
restricted?
* Is drain hose lower than 33" in
standpipe? This can cause siphon-
ing and washer will continue to
fill. See Installation Instructions
for further information.
If water is leaking at
hose connection:
o Disconnect hose from valve.
Remove rubber washer at end of
hose and replace with new
washer. Reconnect hose to valve.
DO NOT overtighten.
[AW/lffiNINGJ Disconnect electri-
cal supply cord before servicing
Electronic Laundry Center° Failure
to disconnect can cause electrical
shock or serious personal injury°
if articles am still wet
at end of spin cycle:
° Is load unbalanced? Unit is
designed to complete cycle with
unbalanced load which could
leave articles damp. Redistribute
articles and touch SPIN ONLY.
o Is drain system clogged or re-
stricted?
If articles are not drying
satisfactorily:
o Is tint screen clean?
Are exhaust duct and vent hood
free of obstruction or lint
blockage?
o Is dryer operating on AIR ONLY
cycle which provides no heat?
o Are there too many articles in
dryer? Check loading section of
this bookleL
o Is metal flexible duct kinked or
pinched?
[AWARNING] Do not use plastic
flexible duct to exhaust dryer.
Replace plastic duct with rigid or
flexible metal duct.
Excessive lint can build up inside
duct work creating a fire hazard and
restricting air flow. Restricted air
flow will increase drying time.
Convenience Light
(Models 91901 and 91951)
Replace convenience light with
fluorescent lamp number
F18T81CW/K24 by following
these steps:
. Disconnect power cord from out-
]eto
* Remove the two access panel
screws. Gently pulI panel down°
o Remove the two screws holding
lens in place.
o Remove the two screws holding
lamp clamps o
° Pull bulb away from socket with
gentle pressure.
o Install new bulb by gently pushing
terminals into sockets,
o Replace clamps, lens, and access
panel securely with screws.
o Connect power cord to outlet°
Drum Light
(Models 91901 and 91951)
Replace drum light with incandes-
cent bulb number 10C7 by following
these steps:
o Disconnect power cord from out-
let.
o Remove lamp cover by turning it
counter-clockwiseo
€, Remove bulb by turning it a
quarter turn to the left and gently
pulling bulb from receptacle.
* Install new bulb and replace lamp
cover.
= Connect power cord to outlet.
Optional ories for your
Kenmore Electronic Laundry Center
available from your nearest Sears Service Center.
• Drying Rack PIN 145283-000
• Syphon Break PIN 076660-000
• Drain Hose, 9 Fto Long PIN !42337-000
,, For additional accessories check Laundry Center Parts List or your local Sears Service Center.
PAGE 16 PIN 131054000 3/92