Kenmore 110.8586# Clothes Dryer User Manual


 
Explosion Hazard
Keep flammable materials and vapors, such as
gasoline, away from dryer.
Place dryer at least 18 inches (46 cm) above the floor
for a garage }nstaHation.
Failure to do so can result in death, e×ploeion, or fire.
You will need
A location that allows for proper exhaust installation. See
"Venting Requirements."
A separate 30-amp circuit.
If using a power supply cord, a grounded electrical outlet
located within 2 ft (61 cm) of either side of the dryer. See
"Electrical Requirements."
A sturdy floor to support the total dryer weight of 200 Ibs
(90.7 kg). The combined weight of a companion appliance
should also be considered.
A level floor with a maximum slope of 1" (2.5 cm) under entire
dryer. (If slope is greater than 1" [2.5 cm], install Extended
Dryer Feet Kit, Part Number 279810.) Clothes may not tumble
properly and automatic sensor cycles may not operate
correctly if dryer is not level.
For a garage installation, you will need to place the dryer at
least 18" (46 cm) above the floor. If using a 13" (33 cm)
pedestal, you will need to place the pedestal at least
6" (15.2 cm) above the floor. If using a 15.5" (39.4 cm)
pedestal, you will need to place the pedestal at least
3" (7.6 cm) above the floor.
Do not operate your dryer at temperatures below 45°F (7°C). At
lower temperatures, the dryer might not shut off at the end of an
automatic cycle. Drying times can be extended.
The dryer must not be installed or stored in an area where it will
be exposed to water and/or weather.
Check code requirements. Some codes limit, or do not permit,
installation of the dryer in garages, closets, mobile homes, or
sleeping quarters. Contact your local building inspector.
Installation clearances
The location must be large enough to allow the dryer door to
open fully.
Dryer Dimensions
501/2"
128.27 crn)
* Most installations require a minimum 51/2'' (14 cm) clearance
behind the dryer for the exhaust vent with elbow. See "Venting
Requirements."
Minimum installation spacing for recessed area, custom
undercounter or closet installation
The following dimensions shown are for the minimum spacing
allowed.
Additional spacing should be considered for ease of
installation and servicing.
Additional clearances might be required for wall, door and
floor moldings.
Additional spacing of 1" (2.5 cm) on all sides of the dryer is
recommended to reduce noise transfer.
For closet installation, with a door, minimum ventilation
openings in the top and bottom of the door are required.
Louvered doors with equivalent ventilation openings are
acceptable.
Companion appliance spacing should also be considered.
Custom undercounter installation - Dryer only
0"* 0"*
(0 ¢m) ' (68.6¢m) (0 cm)
*Additional spacing recommended