John Deere AC-2700GS Washer User Manual


 
36 AC-Series Operator’s Manual-E/F
Service
CHANGING WATER PUMP OIL
IMPORTANT: Change pump break-in oil after first 20
hours of operation and at 250 hour intervals
thereafter.
1. Put unit on level surface.
2. With water owing through pump, run unit for a few
minutes to warm oil.
3. Stop engine and close water supply.
4. Remove drain plug (A) to drain oil into container. Do not
pollute; dispose of waste oil properly.
NOTE: Drain plug (A) is located on bottom of pump on
AC-2000GH, AC-2400GH, AC-2400GS and
AC-2600GH washers. It is located at front end of
pump on AC-2500GH, AC-2700GH, AC-2700GS,
AC-3000GS, AC-3300GH and AC-3500GH.
5. Add SAE75W-90 Synthetic oil through fill tube
on AC-2000GH, AC-2400GH, AC-2600GH and
AC-2400GS or HY-GARD® through dipstick holes in
other models (B). Fill to sight glass or to notch/ring in
dipstick. Oil capacity is:
AC-2000GH ..........................4.5 oz. (0.14 qt., 0.13L)
AC-2400GH ..........................4.5 oz. (0.14 qt., 0.13L)
AC-2400GS .......................... 4.5 oz. (0.14 qt., 0.13L)
AC-2500GH ..........................40.6 oz. (1.27 qt., 1.20L)
AC-2600GH ..........................4.5 oz. (0.14 qt., 0.13L)
AC-2700GH ..........................14 oz. (0.42 qt., 0.40L)
AC-2700GS .......................... 14 oz. (0.42 qt., 0.40L)
AC-3000GS .......................... 14 oz. (0.42 qt., 0.40L)
AC-3300GH ..........................15 oz. (0.47 qt., 0.44L)
AC-3500GH ..........................15 oz. (0.47 qt., 0.44L)
PIC102-101599R0
PIC101-101599R1
AC-2000GH / AC-2400GH
AC-2400GS / AC-2600GH
AC-2500GH
A
A
PIC71•102299R0
B
AC-2700GH / AC-3300GH
AC-2700GS / AC-3000GS / AC-3500GH
B
A