HoMedics IBPS200-C Iron User Manual


 
98
Removing Mineral Buildup
One common problem with steamers is mineral buildup caused by the high
mineral content in many municipal water supplies. Mineral residue inside of the
internal pipes and heater can cause intermittent steaming or in severe cases no
steaming at all.
The best way to avoid this is to use de-mineralized or distilled water in the unit.
The procedure below can be used to clear mineral buildup. If you are unable to
use de-mineralized or distilled water we recommend you use this procedure
monthly to help avoid mineral buildup.
1. Turn the unit off and unplug the power cord.
2. Unscrew and remove the hose from the hose connector on the top of the unit.
3. Remove the pole from the unit.
4. Remove the water tank from the main unit and drain any water in the unit.
5. Make a mixture of 50% vinegar and 50% water. In most cases 1 cup of this
mixture will be sufficient.
6. Slowly pour the water-vinegar mixture into the hose connector.
a. If the internal piping is only partially blocked by mineral buildup, the
water-vinegar mixture will soon start flowing out of the water intake
hole. If this happens proceed to step 8.
b. If the internal piping is completely blocked, continue to pour the
mixture into the hose connector till full.
7. Pour the water-vinegar mixture into the water intake hole until full.
8. Let stand for 40 minutes.
9. Drain the water using the drain plug.
10. Pour clean water through the hose base and water intake hole until the
vinegar smell dissipates.
11. Reassemble the unit and operate normally.
If the procedure above does not return the unit to normal operation, the unit may
need servicing.
Trouble Shooting the Steamer
PROBLEM CAUSE SOLUTION
Steamer fails to heat Steamer not plugged in Plug in to electrical outlet
Auto shut off engaged Check water container to
insure it is not empty. If full, hit
reset ON/OFF switch on side
of unit. If empty, refill and
push reset to begin.
No steam Water level is low Turn ON/OFF switch OFF and
refill water container
Water drips from nozzle Condensation in hose Hold the hose vertically and
allow water to drain back into
tank
Nozzle gurgles Condensation in hose Hold the hose vertically and
allow water to drain back into
tank
Steam is intermittent Sediment build-up in Follow the procedure for
container removing mineral build-up
NOTE: 1. Water mineral content and conditions will vary in different
areas. To insure continued operation of the steamer, never
store without cleaning and removing excess water from the
resevoir and water container.
2.If the reset light comes on with water in the tank you
probably need to declarify (clean) the unit.
3.In areas where the voltage exceeds 120V, it may be
necessary to clean your unit more frequently.
Hose Connector
Water Intake Hole
PS-200C 1/27/05 10:32 AM Page 9