English
15
It is your responsibility
• To connect a qualified electrical installer.
• To be sure that the electrical connection is adequate and in
conformance with CAN1-B149 (.1 or .2) installation codes and/or
local codes.
• A 4 wire, single phase, 115/230-volt, 60-Hz., AC-only electrical
supply is required on a separate 30-amp circuit, fused on both sides
of the line. A time-delay fuse or circuit breaker is recommended.
Connect to an individual branch circuit.
• This dryer is equipped with a CSA International Certified Power Cord
intended to be plugged into a standard 14-30R wall receptacle.
The cord is 5 ft (1.52 m) in length. Be sure wall receptacle is within
reach of dryer’s final location.
4-wire receptacle 14-30R
If using a replacement power supply cord, it is recommended that you use
Power Supply Cord Replacement. For further infromation, please reference the
service numbers located in the “Assistance or Service” section of this manual.
ELECTRICAL REQUIREMENTS
Electrical Shock Hazard
Plug into a grounded 4 prong outlet.
Failure to do so can result in death or electrical shock.
Warning