GE PCVH480EK Washer/Dryer User Manual


 
23
BOTTOM VENTING (cont.)
ADDING A NEW DUCT
Reconnect the cut
portion A of the
duct to the blower
housing.
Tape the elbow
in a 90-degree
position to
prevent rotation.
Insert the elbow
through the rear hole
and connect it to
portion A. Rotate
the elbow through
the bottom opening.
CAUTION:Be sure not to pull or
damage the electrical wires inside the dryer
when inserting the duct.
While still holding down
the pipe and elbow from
the rear opening, screw
the pipes in place with
the previously saved screw.
Apply duct tape
as shown on the joint
between the dryer internal
duct and the elbow.
NOTE: Make sure the tape
covers the screw hole in
portion A where it connects
to the elbow.
CAUTION:Internal duct joints must be
secured with tape; otherwise, they may separate
and cause a safety hazard.
Duct tape
Rear hole
Bottom
opening
Portion “A”
Fixing hole
Installation Instructions
Dryer Exhaust to the bottom of cabinet.
ADDING COVER PLATE TO REAR OF CABINET
(BOTTOM EXHAUST)
WARNING – NEVER LEAVE
THE BACK OPENING WITHOUT THE PLATE.
COVER BACK OPENING WITH A COVER PLATE
(COVER PLATE – WE1M545) AVAILABLE FROM
YOUR LOCAL SERVICE PROVIDER.
Connect standard metal elbows and ducts to
complete the exhaust system. Cover back opening
with a cover plate (Cover Plate – WE1M545)
available from your local service provider.
Insert the tab at the top of the cover plate into the
opening. Fasten screw at the bottom of the cover
plate.
Place dryer in final location.
Cover Plate
Tab
Screw