GE DPVH880EJMG Clothes Dryer User Manual


 
Dryer Exhausting Information – Metal Duct Only
For complete information, see installation instructions packed with your dryer.
Ducting Materials: For best performance, this dryer should be vented with 4” diameter
allrigidmetalexhaustduct.Ifrigidmetalductcannotbeused,thenUL-listedflexible
metal(semi-rigid)ductingcanbeused(KitWX08X10077).Inspecialinstallations,itmay
benecessarytoconnectthedryertothehouseventusingaflexiblemetal(foil-type)duct.
AUL-listedflexiblemetal(foil-type)ductmaybeusedONLYininstallationswhererigid
metalorflexiblemetal(semi-rigid)ductingcannotbeusedANDwherea4”diametercan
be maintained throughout the entire length of the transition duct. Please see installation
instructionpackedwithyourdryerforcompleteinstructionswhenusingflexiblemetal(foil
type) ducting.
Exhaust Length Calculation:
1. Determinethenumberof90°turnsneededforyourinstallation.Ifyouexhausttothe
side or bottom of dryer, add one turn.
2. Themaximumlengthof4’rigid(aluminumorgalvanized)ductwhichcanbetoleratedis
shown in the table.
Aturnof45°orlessmaybeignored.Two45°turnswithintheductlengthshouldbe
treated as a 90° elbow.
A turn over 45° should be treated as a 90° elbow.
Dryers mustbeexhaustedtotheoutside.
Caution: Forpersonalsafetydonotterminateexhaustintoachimney,underanyenclosed
house floor (crawl space), or into an attic, since the accumulated lint could create a fire
hazardormoisturecouldcausedamage.Neverterminatetheexhaustintoacommonduct
orplenumwithakitchenexhaust,sincethecombinationoflintandgreasecouldcreatea
fire hazard.
Exhaustductsshouldbeterminatedinadamperedwallcaptopreventbackdrafts,bird
nesting,etc.Thewallcapmustalsobelocatedatleast12"abovethegroundoranyother
obstruction with the opening pointed Down.
For more information on venting kits and accessories, please call 1-800-GE-CARES.
Listed by
Underwriters
Laboratories
Specification Revised 6/09
270196
DPVH880EJ
GE Profile
7.5 Cu. Ft. Colossal Capacity Electric Dryer
Best performance
Domestic
dryer models
Maximum length of 4"
dia. rigid metal duct
Number
of
90°
turns
Exhaust hood type
A
4"
opening
B
2-1/2"
opening
7.5 and 7.3 cu. ft.
capacity electric
and gas dryers
0
1
2
3
4
150 ft.
140 ft.
130 ft.
120 ft.
110 ft.
127 ft.
117 ft.
107 ft.
97 ft.
87 ft.
A
4
B
2-1 / 2
A