Special Installation Requirements:
Stacked Installation:
•Bracketsforstackingdryeroverwasherareavailableatanadditonalcost
Alcove or Closet Installation:
•Ifyourdryerisapprovedforinstallationinanalcoveorcloset,itwillbe
stated on a label on the dryer back.
•ThedryerMUSTbeexhaustedtotheoutside.
•Minimumclearancesbetweendryercabinetandadjacentwallsorother
surfaces are: 0" either side, 3" front and rear
•Minimumverticalspacefromfloortooverheadcabinets,ceilings,etc.is52".
•Closetdoorsmustbelouveredorotherwiseventilatedandmustcontaina
minimumof60sq.in.ofopenareaequallydistributed.Ifthisclosetcontains
both a washer and a dryer, doors must contain a minimum of 120 sq. in. of
open area equally distributed.
•Nootherfuel-burningapplianceshallbeinstalledinthesameclosetwith
a gas dryer.
Bathroom or Bedroom Installation:
•ThedryerMUSTbeexhaustedtotheoutdoors.
•Theinstallationmustconformwiththelocalcodes,orintheabsenceof
localcodes,withtheNationalElectricCodeandNationalFuelGasCode,
ANSIZ223forgasdryers.
Minimum Clearance other than Alcove or Closet Installations:
•Minimumclearancestocombustiblesurfaces0"bothsides,3"rear.
For more information on venting kits and accessories,
please call 1-800-GE-CARES.
Stacked Dimensions (in inches)
79"
Harmony
27
15
29-1/2
Storage Pedestal Dimensions
(in inches)
SPSD157JMG - Champagne
SPSD157JMV - Vermillion Red
SPSD157JWW - White
Thisoptional15"pedestalraises
the door opening and height of
the washer or dryer. Feet on 15"
pedestalallowittoadjustto15-
3/8" height.
Listed by
Underwriters
Laboratories
Specification Revised 6/09
270196
DPVH880EJ
GE Profile
7.5 Cu. Ft. Colossal Capacity Electric Dryer