GE 14-A037 Washer/Dryer User Manual


 
36"
25-3/4"
53-1/2"
70-5/8"
25-3/4"
26-3/4"
G u i d e l i n e s t o
• This laundry pair requires a
53-1/2" wide space. No special
installation requirements, install
in the same manner as any other
laundry pair.
• Allow additional 3" minimum
behind the dryer for duct
connection and 1-1/2" minimum
behind the washer for standpipe.
No trim kits to order, no
additional cost.
Mounting brackets are
supplied with the dryer.
• Remove washer top cap,
install brackets and
mount the dryer over
the washer.
• The stacked pair is only
70-5/8" tall. The dryer
door will be eye-level,
an easy reach for most
users.
• Install the washer and
dryer according to the
installation instructions
packed with the
products.
Stacked
4
Optimize space and efficiency.
Side-By-Side
Washer:
• Install separate Hot & Cold faucets within 42" of the
washer inlet.
• Provide a standpipe, 1-1/4" min. dia. and 24" min.,
58" max. high. The attached drain hose will reach
a 58” standpipe.
• The washer must be supplied with 120 volt, 60 Hz.,
and connected to an individual, properly polarized
and grounded branch circuit protected by a 15 amp
circuit breaker or time delay fuse. The 3 prong
receptacle must be located where it will be accessible
when the washer is installed. Power cord
length is 36".
• Follow the installation instructions packed with the
product to remove shipping bolts and materials.
• Some installations require a pan to hold the washer.
Local codes to apply. Pan size to fit washer.
* Note: Standpipes up to 96" high can be accommodated
with a longer drain hose.
Dryer:
• Provide 4" min. dia. rigid metal duct for best
performance. Plan the shortest and straightest duct
run possible. The dryer must ALWAYS be exhausted
to outdoors.
• Electric models can exhaust 4 ways, from the right
or left side, rear or bottom. Gas models can exhaust
3 ways, from the right side, rear or bottom. Both gas
and electric models are shipped for rear exhaust.
• The dryer must be connected to an individual
branch circuit protected by the required time delay
fuses or circuit breakers. 208V or 240V installation
requires 30 amps. (Gas dryers require 120V, 60Hz,
15 or 20 amp circuit.) Locate the receptacle where
it will be accessible when the dryer is installed.
Power cord length is 36".
• Follow the installation instructions packed with the
product to complete the installation.
Note: Do not discard shipping bolts, clips or any parts
removed during installation. The consumer should
keep unused parts for possible future use or
shipping.
Washer Clearances:
• Allow 1-1/2" from the back of the washer to rear wall
for drain hose and standpipe. 0" to both sides.
Dryer Clearances:
• 0" to either side, 3" rear, 3" clearance at the front,
when installed into a recess or closet. When
installed in a closet allow a min. of 120 sq. inches
of opening such as louvers on the door.
• For complete installation instructions refer to washer
Pub. No. 31-2819 and dryer Pub. No. 49-9963.