9
INSTALLATION INSTRUCTIONS
If you have an uncontrolled water heating source (eg a wet back or solar heating
system) you should fit a Hot ‘N’ Safe Valve. This will ensure the hot water temperature
remains within safe limits.
Hot ‘N’ Safe Valves available are:
RMC TVA 50HF
RMC TVA 75HFS
Adjustable between 35°C – 55°C
RMC TVA 50HP
For instantaneous gas hot water supply
Water supply requirements:
Inlet water pressure: Maximum 1MPa (150psi), Minimum 30kPa (4.5psi)
Inlet water flow rate: Minimum 6litres/minute
Cold supply only:
If you only have a cold water supply, the inlet valve cap (blanking cap) which came with
your washer must be connected to the hot inlet valve. The cap prevents water leaking
out of the hot valve. This appliance incorporates backflow protection complying with
AS3500.1. No further backflow protection is required for connection to the water supply.
Note: your washer has an internal heater to heat water. If you do not connect a hot
water inlet hose, your washer will automatically recognise there is no hot water supply
and its internal heater will heat the cold water to the required cycle temperature.