6
Spade terminals
with upturned ends
Ring
terminals
This blade connects
to this conductor.
Neutral
3/4” UL-listed
strain relief
Neutral
(white)
Follow the steps below to connect a 3-wire power cord:
1. Turn the power off at the breaker/fuse box.
2. Remove terminal block cover.
3. Use the strain relief attached below the terminal block opening.
4. Loosen or remove center terminal block screw.
5. Connect neutral (white) wire of power supply cord to the center, silver-
colored terminal screw. Tighten screw.
6. Connect the other wires to outer screws.
7. Tighten the strain relief screws.
8. Replace terminal box cover on back of dryer.
9. Plug dryer into wall receptacle.
10. Turn power on at breaker/fuse box.
5
7
6
4
ELECTRICAL CONNECTIONS
The power supply cord must be grounded. If the machine is to be used in a wet area, the supply must be
protected by a residual current device. Connection to a permanently wired supply point must be made only
by a qualified electrician.
As supplied: Single-phase, 230 V, 60 Hz, 2500 Watt heater, 30 A fuse required
CONNECTING A 3-WIRE POWER CORD
WARNING!
Before starting this procedure, be sure the power is turned off at the breaker/fuse box.
You will need a 3-wire power supply cord with three No. 10 copper wires and a matching 3-wire receptacle
of NEMA Type 10-30R, as illustrated below:
The numbers in the
illustration below correlate
to the step numbers.