Electrolux 137018200 A Clothes Dryer User Manual


 
12
Installation Instructions
Electrical connection (non-Canada) - 3 wire cord
Turn off power supply to outlet. 1.
Remove the screw securing the terminal block 2.
access cover in the lower corner on the back of
the dryer.
Install a UL-approved strain relief according 3.
to the power cord/strain relief manufacturer’s
instructions in the power cord entry hole below
the access panel. At this time, the strain relief
should be loosely in place.
ThreadanUNPLUGGED,UL-approved,30amp.4.
powercord,NEMA10-30typeSRDT,throughthe
strain relief.
Attachthepowercordneutral(centerwire)5.
conductor to the SILVER colored center
terminal on the terminal block. Tighten the
screw securely.
Attach the remaining two power cord outer 6.
conductorstotheouter,BRASScolored
terminals on the terminal block. Tighten both
screws securely.
WARNING
ELECTRICALSHOCKHAZARD
Do not make a sharp bend or crimp wiring/
conductor at connections.
3-wire receptacle
(NEMAtype10-30R)
Internal ground
(GREEN screw)
Install
UL-approved
strain relief here
Terminal screw
recovery slot
Line 1
(BRASS terminal)
Neutral
(SILVER terminal)
Line 2
(BRASS terminal)
Access cover
screw
Terminal
block
Neutral
(center wire)
30 AMP
NEMA 10-30
NOTE
If a terminal screw falls during cord installation,
it can be retrieved in the terminal screw recovery
slot below the access panel.
WARNING
ELECTRICALSHOCKHAZARD
Failure to disconnect power source before servicing
couldresultinpersonalinjuryorevendeath.
Follow manufacturer’s guidelines for firmly 7.
securing the strain relief and power cord.
Reinstall the terminal block cover.8.
DO NOT remove
internal ground in
a 3-wire system!!
Neutral
terminal
IMPORTANT
If moving dryer from a 4-wire system and
installing it in a 3-wire system, move the internal
ground from the center terminal back to the
GREENscrewnexttotheterminalblock.