19
EN
For the condenser;
Hot and humid air in the condenser is cooled
with the cold air from the room. Thus,
the humid air circulating in your dryer is
condensed and then pumped into the tank.
C Clean the condenser after every 30 drying
cycles or once a month.
To clean the condenser:
1. If a drying process has been carried out,
open the door of the machine and wait until
it cools down.
2. Unlock the 2 condenser locks after opening
the kick plate.
3. Pull out the condenser.
4. Clean the condenser by applying
pressurized water with a shower armature
and wait until the water drains.
5. Place the condenser in its housing. Fasten
the 2 locks and make sure that they are
seated securely.
6. Close the kick plate cover.