Ariston ARXL 129 W SP Washer User Manual


 
6
NA
Electrical
•MachineVoltage/Amperage-120V,60Hz,4Amp.
•Connection-3-prongplugwith6’cordisprovidedwith
themachine.
•Circuit/Protector-3-wiresinglephase,120V,60Hz,AC,
onaseparate15Ampcircuit.
Technical Information
Technical data
Model
ARXL129WSP
Dimensions
width:23.4””(59.5cm)
height:33.24””-33.75””(84.5-85.7cm)
depth:22””(55.9)cm
Weight
148 lbs
Minimum Installa-
tion Clearances
Sides: 0””
Front / Back: 1””
Capacity
Washing:2to15lbs.(1to7kg)
Electrical
connections
Voltage:120Volts,4A,60Hz
Water
connections
Max.Pressure:0.69MPa(6.9bar),100psi
Min.Pressure:0.05MPa(0.5bar),7.2psi
Max. Spin speed
upto1200RPM
Indesit Company offers their customers
productswiththeENERGYSTARLabel.
This appliance was tested by UL and
conformswithbothCanadianandU.S.
UL safety requirements and displays
theirMark.
C
U
L
US LISTED
®
•Inserttheoutletendofthedrainhoseintothestandpipe,
wallorfloordrain(Fig.6).NOTE:Theoutletendofthe
drain hose MUST be at least 20” (50 cm) above the base
ofthemachine.Nomorethan6”ofthedrainhoseshould
beinsertedintothedrainpipetopreventsiphoning.
•Useastrap,cabletie,orsimilaritemtoholdthehoseor
theU-Clampinplace.
Under Sink Method
1. Cut the blocked end of
theundersinkdrainageunit.
2. Fix the hooked end sup-
porta minimum of 620 mm
fromthefloor.
3. Use a hose clip clamp to
securely attach the grey drai-
nage hose end to the under
sink drainage unit using a
hose.clamp
20" (62 cm) min.
34" (86 cm) max.
Standpipe
"Y" Tail Piece
This connection MUST be
before drain trap and at
least 20" (50.8 cm) above
the floor where washer will
be installed.
Cable tie
Floor Standpipe w/ "Y" Branch Tail Piece
Fig. 7
20" (50 cm) min.
with an air break
25" (62 cm) min.
34" (86 cm) max.
6" max.
Standpipe
Floor Standpipe
Fig. 6
U-Clamp