American Dryer Corp. Super AD-30 Clothes Dryer User Manual


 
32
I. PREPARATION FOR OPERATION
The following items should be checked before attempting to operate the dryer:
1. Read ALL "CAUTION," "WARNING," and "DIRECTION" labels attached to the dryer.
2. Check incoming supply voltage to be sure that it is the same as indicated on the dryer data label affixed to the
back side of the top front control/service door.
3. GAS MODELS -check to assure that the dryer is connected to the type of heat/gas indicated on the dryer
data label.
4. GAS & ELECTRIC MODELS - the sail switch damper assembly was installed and adjusted at the
factory prior to shipping. However, each sail switch adjustment must
be checked to assure that this important safety control is functioning.
5. Check bolts, nuts, screws, terminals, and fittings for tightness.
6. GAS MODELS - be sure that ALL gas shut-off valves are in the open position.
7. Check ALL back guard panels and service box covers have been replaced.
8. Make sure the lint coop support bracket has been removed.
9. Check the lint door to assure that it is closed and secured in place.
IMPORTANT: If during installation the lint door safety chain was disconnected, it must be
reconnected or personal injury may result.
10. Rotate the basket (tumbler) by hand to be sure it moves freely.
11. STEAM MODELS - check to insure ALL steam shut-off valves are open.
12. STEAM MODELS - check to insure that a clean, dry, regulated air supply (80 psi) is on the dryer (with air
operated DAMPER SYSTEM ONLY).