23
NOTE: Contact Factory for electrical information not listed.
NOTE: ADC reserves the right to make changes in specifications at any time, without notice or
obligation.
SUPER ADG-30DS (Gas) NON-REVERSING
SUPER ADS-30DS (Steam) NON-REVERSING
ELECTRIC SERVICE SPECIFICATIONS (PER DRYER)
IMPORTANT: 208 VAC and 230/240 VAC ARE NOT THE SAME. When ordering, specify exact voltage.
NOTE: A. Fuse ratings are dual-element, time-delay, current limiting, class RK1 or RK5 ONLY.
B. Circuit breakers are thermal magnetic (industrial) type ONLY. For others, calculate/verify correct
breaker size according to appliance amp draw rating and type of breaker used.
C. Circuit breakers for 3-phase dryers must be 3-pole type.
SERVICE
VOLTAGE
PHASE
WIRE
SERVICE
APPROX. AMP
DRAW
FUSING
CIRCUIT
BREAKER
60 HZ 50 HZ
Dual Element
Time Delay
120 2 13 --- 17.5 25
208 2 7.6 --- 12 15
230/240 2 7 4.9 12 15
208 3 4.8 --- 6.25 15
230/240 3 5 5.5 6.25 15
380 3/4 --- 3 5 15
416 3/4 --- 3.1 5 15
460/480 3/4 2.8 --- 4.5 15
575 3 2.5 --- 4.5 15
SUPER ADG-30DS (Gas) REVERSING
SUPER ADS-30DS (Steam) REVERSING
ELECTRIC SERVICE SPECIFICATIONS (PER DRYER)
IMPORTANT: 208 VAC and 230/240 VAC ARE NOT THE SAME. When ordering, specify exact voltage.
NOTE: A. Fuse ratings are dual-element, time-delay, current limiting, class RK1 or RK5 ONLY.
B. Circuit breakers are thermal magnetic (industrial) type ONLY. For others, calculate/verify correct breaker
size according to appliance amp draw rating and type of breaker used.
C. Circuit breakers for 3-phase dryers must be 3-pole type.
SERVICE
VOLTAGE
PHASE
WIRE
SERVICE
APPROX. AMP
DRAW
FUSING
CIRCUIT
BREAKER
60 HZ 50 HZ
Dual Element
Time Delay
208 3 4.8 --- 6.25 15
230/240 3 5 5.5 6.25 15
380 3/4 --- 3 5 15
416 3/4 --- 3.1 5 15
460/480 3/4 2.8 --- 4.5 15