American Dryer Corp. MLG-130DR (HSI) Clothes Dryer User Manual


 
40
SECTION IX
BURNER and LINT (TUMBLER) CHAMBER
MANUAL RESET HI-LIMIT INSTRUCTIONS
(FOR PHASE 6 MODELS)
This dryer was manufactured with a manual reset burner hi-limit (gas models only) and tumbler/lint chamber
hi-limit thermostat which is monitored by the Phase 6 computer. If either manual reset thermostat is open prior to
start of the drying cycle, the dryer will start momentarily and then shut down, the Phase 6 computer will display
an error code with an audio indication. If the tumbler/lint chamber hi-limit thermostat is open, the display will read
dRUM SAFETY FAIL. If the burner hi-limit thermostat is open, the display will read bURNER SAFETY
FAIL.
If either manual reset hi-limit thermostat opens during a drying cycle, the display will show the applicable
error code described above along with an audio indication. If the drum temperature is above 100º F (38º C), the
dryer will continue to run with no heat for three (3) minutes or until the drum temperature has flattened below
100º F (38º C). The clear/stop button on the Phase 6 keyboard (touchpad) must be pressed to clear the error
condition. The open manual reset hi-limit thermostat must be reset manually prior to the start of the next
cycle.
This hi-temperature condition may be caused due to a restricted exhaust, poor airflow or improper burner
operation.
The location of the burner hi-limit is on the right side of the burner box and the tumbler hi-limit is located in
the lint chamber area.
WARNING: Discontinue power to dryer before attempting to reset hi-limit.
IMPORTANT
This dryer is equipped with a burner hi-
limit and tumbler/lint chamber hi-limit ther-
mostat which must be reset manually.
WARNING: Discontinue power to dryer
before attempting to reset hi-limit.
ADC P/N: 114093