36
SECTION VII
REVERSING TIMER SPIN/DWELL ADJUSTMENTS
Timer models have an electronic reversing timer in the electrical service box which is located in the upper left
rear area of the dryer.
Both the Dwell (stop) Time and the tumbler (basket) Spin Time are adjustable by mode selection switches
located on the electronic timer (as noted in the illustration below).
TIMING LEGEND
SPIN TIME
Switch Position Number 1 2 3 4 5
Time in Seconds* 30 60 90 120 150
DWELL (Stop) TIME
Switch Position Number 1 2 3 4 5
Time in Seconds* 5 6 8 10 12
* Values shown are +/- 1 second.