SECTION X
BURNER AND BASKET (TUMBLER)/LINT CHAMBER
MANUAL RESET HI-LIMIT INSTRUCTIONS
I M P O R T A N T
MANUAL RESET HI-LIMIT INSTRUCTIONS
FOR PHASE 7 MODELS
This dryer was manufactured with a manual reset burner hi-limit and basket (tumbler)/lint chamber
hi-limit thermostat which is monitored by the Phase 7 computer. If the burner is open prior to start of the
drying cycle, the dryer will start momentarily and then shut down, the Phase 7 computer will display
BURNER HIGH LIMIT FAULT with an audio indication. If the basket (tumbler)/lint chamber hi-limit
thermostat is open prior to start, the display will read EXHAUST HIGH LIMIT FAULT with an audio
indication as well.
If either manual reset hi-limit thermostat opens during a drying cycle, the display will show the
applicable error code described above, along with an audio indication. If the drum temperature is above
100° F (38° C), the dryer will continue to run with no heat for 3 minutes or until the drum temperature has
dropped below 100° F (38° C). The clear/stop button on the Phase 7 keyboard (touch pad) must be
pressed to clear the error condition. The open manual reset hi-limit thermostat must be reset manually
prior to the start of the next cycle.
This hi-temperature condition may be caused due to a restricted exhaust, poor airflow, or improper
burner operation.
The location of the burner hi-limit is on the right side of the burner box and the basket (tumbler) hi-limit
is located in the lint chamber area.
WARNING: Discontinue power to dryer before attempting to reset hi-limit.
IMPORTANT
This dryer is equipped with a burner
hi-limit and tumbler/lint chamber hi-limit
thermostat which must be reset manually.
WARNING: Discontinue power to dryer
before attempting to reset hi-limit.
ADC P/N:114093