American Dryer Corp. ML-75DIII Clothes Dryer User Manual


 
47
2. For Models With Johnson Controls Direct Spark Ignition (DSI) Module (G760)
Theory Of Operation:
Start the drying cycle. When the gas burner
ignites within the chosen trial for ignition time
(6-seconds), the flame sensor detects gas
burner flame and signals the DSI module to
keep the gas valve open...as long as there is
a call for heat. The DSI module will
LOCKOUT if the gas burner flame is not
sensed at the end of the trial for ignition
period. The trial for ignition period
will be
repeated for a total of three (3) retries/trials
(the initial try and two [2] more retries/trials).
If the flame
is not sensed at the end of the
third retry/trial (inter-purge period of
30-seconds) the DSI module will
LOCKOUT (light emitting diode [L.E.D.]
flashes).
A steady L.E.D. indicator indicates normal
operation.
No L.E.D. indicator indicates a power or an
internal failure has occurred.