b. Electric Models Only
IMPORTANT: Figures shown are for non-reversing models only. For reversing models contact the
factory.
IMPORTANT: The dryer must be connected to the electric supply shown on the data label that is
affixed to the left side panel/wall area behind the control door. In the case of 208
VAC or 240 VAC, the supply voltage must match the electric service specifications
of the data label exactly.
IMPORTANT: The wire size must be properly sized to handle the related current.
WARNING: 208 VAC and 240 VAC ARE NOT THE SAME. Any damage done to dryer
components due to improper voltage connections will automatically VOID THE
WARRANTY.
NOTE: ADC reserves the right to make changes in specifications at any time without notice or
obligation.
IMPORTANT: 3-phase (3ø) figures shown are for a 3-wire service only.
APPROX.
AMP DRAW
MLE-75 (ELECTRIC)
ELECTRICAL SERVICE SPECIFICATIONS (PER DRYER)
IMPORTANT: 208 VAC and 240 VAC ARE NOT THE SAME . When ordering, specify exact voltage.
NOTES: A. Fuse ratings are dual element, time delay, current limiting, class RK1 or RK5 ONLY.
B. Circuit breakers are thermal/magnetic (industrial) motor curve type ONLY. For others, calculate/verify correct breaker size according to appliance amp draw
rating and type of breaker used.
C. Circuit breakers for 3-phase (3ø) dryers must be 3-pole type.
APPLIED VOLTAGE/PHASE
KW 208/1ø (60 Hz) 240/1ø (60 Hz) 208/3ø (60 Hz) 240/3ø (50/60 Hz) 380/3ø (50 Hz) 416/3ø (50 Hz) 460/3ø (60 Hz)
20 104 90 --- --- 33 --- ---
24 --- --- 72 63 --- 36 33
30 --- --- 88 77 --- 45 41
33 --- --- --- --- 53 --- ---
36 --- --- 105 92 --- 53 48
40 --- --- --- --- --- 59 ---