American Dryer Corp. MDG-75 Clothes Dryer User Manual


 
51
U. Heating unit
is not operating (no heat)...no voltage at heating unit (i.e., Gas Model)
when dryer is first started and both the heat indicator dot and the "HEAT" output L.E.D. (light
emitting diode) is not on...
1. Failed microprocessor controller (computer).
V. Heating unit is not operating (no heat)...no voltage at heating unit (i.e., Gas Model - HSI module)
GAS MODELS ...
1. Fault in Hot Surface Ignition (HSI) system ...
a. Ignitor glows, but no ignition and HSI module "LOCKS-OUT" ("red" L.E.D. [light emitting diode]
indicator flashes) ...
1) Flame probe assembly is out of adjustment or has failed.
2) Severe air turbulence.
3) Failed HSI module.
4) Failed gas valve.
b. Ignitor glows, burner lights but burner goes off right away ...
1) Flame probe assembly is out of adjustment or has failed.
2) Sail switch is fluttering ...
a) Lint screen is dirty.
b) Restriction in exhaust duct work.
c. Hot Surface Ignitor does not glow and HSI module "LOCKS-OUT" ("red" L.E.D. [light emitting
diode] indicator flashes) ...
1) Fault in Ignitor wiring...break or loose connection.
2) Failed Ignitor Assembly.
3) Failed HSI module.