American Dryer Corp. MDG-75 Clothes Dryer User Manual


 
37
B. ADJUSTMENTS
7 DAYS AFTER INSTALLATION and EVERY 6 MONTHS THEREAFTER
Inspect bolts, nuts, screws, (bearing set screws), non-permanent gas connections (unions, shut-off valves,
orifices, and grounding connections). Motor and drive belts should be examined. Cracked or seriously
frayed belts should be replaced. Tighten loose V-belts when necessary. Complete operational check of
controls and valves. Complete operational check of ALL safety devices (door switches, lint drawer
switch, sail switch, burner and hi-limit thermostats).