22 Maytag Co. 113201-7
2. Mechanical Drop/Rotary Coin Meter or Slide Coin Meter
a. Insert coin and turn knob (rotary type meter), or for slide meter unit, push in coin chute.
b. Select temperature.
c. Push the “Start” button.
d. To stop dryer, open the main door.
K. SHUTDOWN INSTRUCTIONS
If the dryer is to be shutdown (taken out of service) for a period of time, the following must be performed:
1. Discontinue power to the dryer either at the external disconnect switch or the circuit breaker.
2. Discontinue the gas supply:
a. SHUT OFF
external gas supply shutoff valve.
b. SHUT OFF
internal gas supply shutoff valve located in the gas valve burner area.