American Dryer Corp. MD-170 Clothes Dryer User Manual


 
65
2.
For models manufactured with Johnson Controls DSI (Direct Spark Ignition)
Module (G760)
Theory Of Operation;
Start the drying cycle. When the gas burner
ignites within the chosen trial for ignition
time (6-seconds), the flame sensor detects
gas burner flame and signals the Direct
Spark Ignition (DSI) module to keep the
gas valve open...as long as there is a call
for heat. The DSI module will
LOCKOUT if the gas burner flame is
not sensed at the end of the trial for ignition
period. The trial for ignition period will be
repeated for a total of three (3) retries/trials
(the initial try and two [2] more retries/
trials). If the flame is not sensed at the
end of the third retry/trial (inter-purge period
of 30-seconds) the DSI module will
LOCKOUT (L.E.D. [light emitting
diode] flashes).
A steady L.E.D. (light emitting diode)
indicator indicates normal operation.
No L.E.D. (light emitting diode) indicator
indicates a power or an internal failure has
occurred.