American Dryer Corp. ADG-78 II Clothes Dryer User Manual


 
14
To compensate for the use of registers or louvers used over the openings, this make-up air must be increased by
approximately thirty-three percent (33%). Make-up air openings should not be located in an area directly near
where exhaust vents exit the building.
It is not necessary to have a separate make-up air opening for each dryer. Common make-up air openings are
acceptable. However, they must be set up in such a manner that the make-up air is distributed equally to ALL
the dryers.
EXAMPLE: For a bank of four (4) dryers, two (2) unrestricted openings measuring 2 feet by 1-1/2 feet
(6 square feet) is acceptable.
Allowances must be made for remote or constricting passageways or where dryers are located at excessive
altitudes or predominantly low pressure areas.
IMPORTANT:
Make-up air
must be provided from a source free of dry cleaning solvents fumes.
Make-up air that is contaminated by dry cleaning solvent fumes willresult in
irreparable damage the motors and other dryer components.
NOTE:
Component failure due to dry cleaning solvent fumes will
VOID THE WARRANTY.