American Dryer Corp. AD-81 III Clothes Dryer User Manual


 
4
American Dryer Corp.
113159-2
SECTION II
SPECIFICATIONS/COMPONENT IDENTIFICATION
A. SPECIFICATIONS
Shaded areas are stated in metric equivalents 4/27/04
* Air-operated steam damper system must be provided with clean, dry and regulated 80 psi +/- 10 psi (5.51 bar +/- 0.69 bar) air supply.
** Water supply must be 40 psi +/- 20 psi (2.75 bar +/- 1.37 bar) for the fire suppression system to operate properly.
IMPORTANT: Steam dryers must be provided with a clean, dry, and regulated 80 psi +/- 10 psi
(5.51 bar +/- 0.68 bar) air supply. Air volume requirement is 0.75 cfh (cubic feet per
hour) (0.02 cmh [cubic meters per hour]).
NOTE: ADC reserves the right to make changes in specifications at any time without notice or
obligation.
TUMBLER DIAMETER 37”
94 cm
TUMBLER DEPTH 36”
91.5 cm
TUMBLER VOLUME 22.4 cu ft
0.634 cu m
TUMBLER MOTOR 1/2 hp
0.373 kW
BLOWER MOTOR 3 hp
2.2 kW
DOOR OPENING (DIAMETER) 21-1/2”
54.6 cm
EXHAUST CONNECTION (DIAMETER) 14”
35.56 cm
AIRFLOW 1,700 cfm
48.14 cmm
DRYERS PER 20’/40’ CONTAINER 10 / 20
DRYERS PER 48’/53’ TRUCK 24 / 26
WATER CONNECTION** 3/4”-11.5 NH
VOLTAGE AVAILABLE 208-480v 3ø 3, 4w 50/60 Hz
APPROX. NET WEIGHT 833 lbs
377.8 kg
APPROX. SHIPPING WEIGHT 883 lbs
400.5 kg
HEAT INPUT 270,000 Btu/hr
68,040 kcal/hr
INLET PIPE CONNECTION 1” F.N.P.T.
VOLTAGE AVAILABLE 208-480v 3ø 3, 4w 50/60 Hz
APPROX. NET WEIGHT 928 lbs
420.9 kg
APPROX. SHIPPING WEIGHT 978 lbs
443.6 kg
COMPRESSED AIR VOLUME 0.75 cfh
0.02 cmh
COMPRESSED AIR CONNECTION 1/8” F.N.P.T.
STEAM CONSUMPTION 375 lbs/hr
170.5 kg/hr
OPERATING STEAM PRESSURE 125 psi max
8.6 bar
BOILER HP NORMAL LOAD 11
SUPPLY CONNECTION 1” F.N.P.T.
RETURN CONNECTION 1” F.N.P.T.
GasSteam*