3) Failed Direct Spark Ignition (DSI) module.
4) Failed gas valve.
b. Ignitor sparks, burner lights but goes off right away...
1) DSI ignitor/flame-probe is out of adjustment or has failed.
2) Sail switch is fluttering...
a) Lint screen is dirty.
b) Restriction in exhaust ductwork.
c. Ignitor
does not spark and module locks out (“RED” indicator stays on)...
1) Fault in high voltage (HV) wire...break or loose connection.
2) Failed ignitor probe assembly.
3) Failed DSI module.
ELECTRIC MODELS...
1. Failed oven contactor/coil.
2. Failed electric heating element(s).
STEAM MODELS...
1. Air-operated system...
a. No (external) compressed air (80 PSI [5.51 bar] is required) to steam damper solenoid.
b. Failed steam damper pneumatic solenoid.
c. Steam damper stuck in closed position, check for obstruction.
d. Leak in pneumatic system.
e. Failed steam damper air piston.
f. Flow control valve misadjusted.
2. Electrical mechanical system...
a. Failed electrical mechanical motor.
b. Steam damper stuck in closed position...check for obstruction.