American Dryer Corp. AD-75HS Clothes Dryer User Manual


 
32
3.
Steam Damper Air System Connections
The ADS-75 is manufactured with a pneumatic (piston) damper system which requires an external supply of
compressed air. The air connection is made to the steam damper solenoid valve which is located at the rear
inner top area of the dryer just in front of the electric service relay box.
b. Air Connection
Air connection to system --- 1/8-inch N.P.T.
c. No air regulator or filtration is provided with the dryer. External regulation/filtration of 80 psi must be
provided. It is suggested that a regulator/filter gauge arrangement be added to the compressed air line just
before the dryer connection. This is necessary to insure that correct and clean air pressure is achieved.
a. Air Requirements
&