BEFORE YOU START!
CHECK LOCAL CODES AND PERMITS
Call your local water company or the proper municipal authority for information regarding local codes.
IMPORTANT: It is your responsibility to have ALL plumbing connections made by a qualified professional
to assure that the plumbing installation is adequate and conforms to local, state, and
federal regulations or codes.
IMPORTANT: It is the installation or owners responsibility to see that the necessary or required water,
water pressure, pipe size, or connections are provided. Manufacturer assumes no
responsibility if the sensor activated fire extinguishing (S.A.F.E.) system is not connected,
installed, or maintained properly.
INSTALLATION
1. Requirements
The inlet water connection to the dryer is a 1/2” M.P.T., the S.A.F.E. system must be supplied with a
minimum water pipe size of 1/2-inch and be provided with 40 PSI +/- 20 PSI (2.75 bar +/- 1.37 bar) of
pressure. For use of optional manual bypass, a second source with the same piping and pressure requirements
is required.
Flexible 1/2 feeds must be provided to avoid damage to electric water solenoid valve by vibration.
IMPORTANT: Flexible supply line/coupling must be used. Solenoid valve failure due to hard
plumbing connections WILL VOID WARRANTY.
If the rear area of the dryer, or the water supply is located in an area where it will be exposed to cold/
freezing temperatures, provisions must be made to protect these water lines from freezing.
WARNING: If the water in the supply line or water solenoid valve freezes, the S.A.F.E. system will
be INOPERATIVE!!
IMPORTANT: Appliance is to be connected to the water mains using a new hose-set and the old
hose-sets should not be reused.