American Dryer Corp. AD-24 Phase 7 Clothes Dryer User Manual


 
113222-5 www.amdry.com 45
S.A.F.E. SYSTEM DIAGNOSTICS MESSAGES
OPEN THERMISTOR PROBE – This message indicates that the S.A.F.E. system thermistor probe either is not
connected or is damaged. If this condition is detected, the Phase 7 non-coin control will immediately enter
S.A.F.E. SYSTEM DISABLED mode.
SHORTED THERMISTOR PROBE – This message indicates that the S.A.F.E. system thermistor probe is
damaged or the wiring is shorted. If this condition is detected, the Phase 7 non-coin control will immediately enter
S.A.F.E. SYSTEM DISABLED mode.
DISCONNECTED WATER VALVE – This message indicates that the water valve is open or that it
is not
connected to the control. If this condition is detected, the Phase 7 non-coin control will continue to monitor the
condition for a period of 5 minutes before entering S.A.F.E. SYSTEM DISABLED mode. Once the condition is
corrected, the control will continue to monitor the condition for 1 minute before exiting S.A.F.E. SYSTEM
DISABLED mode.
SHORTED WATER VALVE – This message indicates that the water valve is shorted or that the wiring to the
valve is shorted. If this condition is detected, the Phase 7 non-coin control will continue to monitor the condition
for a period of 5 minutes before entering S.A.F.E. SYSTEM DISABLED mode. Once the condition is corrected,
the control will continue to monitor the condition for 1 minute before exiting S.A.F.E. SYSTEM DISABLED
mode.
WATER NOT CONNECTED – This indicates that there is no water pressure at the water valve. This will occur
if water is not connected to the dryer, or if there is low water pressure in the water line coming to the dryer. This
could also signify a defective pressure switch or defective wiring to the pressure switch. If this condition is
detected, the Phase 7 non-coin control will continue to monitor the condition for a period of 5 minutes before
entering S.A.F.E. SYSTEM DISABLED mode. Once the condition is corrected, the control will continue to
monitor the condition for 1 minute before exiting S.A.F.E. SYSTEM DISABLED mode.
STARTING A CYCLE
WHEN COMPUTER IS IN “S.A.F.E. SYSTEM IS DISABLED” MODE
NON-COIN – When the S.A.F.E. system is disabled, the user can still start a cycle. However, when a cycle is
started, the control will display the following message: “S.A.F.E. SYSTEM IS DISABLED. PRESS ‘START’ TO
CONTINUE.” This message will be displayed every time a cycle is started, until the disabling condition has been
corrected.
COIN – When the S.A.F.E. system is disabled, the user can still start a cycle. Simply insert credit and select a
cycle to start.