Alliance Laundry Systems WF400 Washer User Manual


 
4
30
Table 1
The machine is delivered with hoses with 3/4" connections. These hoses t the water
inlet valves of the machine and the main water inlet taps. All the inlet valves have to be
connected. To ensure the optimal functioning of the water inlet valves, the water pressure
on the inlet should be between 3 and 5 bar (40 and 80 psi). If the pressure is too low, the
cycle time will increase considerably.
In case of boiler fed machines, a minimum of hot water of 90°C - 194°F should be
available per unit. (See Table 1)
MODEL
Min Contents Boiler
METRIC US
For the WF150 = WF150, IWF150, IWF033, CWF033 116 l. 4.09 ft³
For the WF185 = WF185, IWF185, IWF040, CWF185, CWF040 145 l. 5.12 ft³
For the WF235 = WF235, IWF235, IWF055, CWF235, CWF055 150 l. 5.29 ft³
For the WF305 = WF305, IWF305, IWF075, CWF305, CWF075 180 l. 6.35 ft³
For the WF400 = WF400, IWF400, IWF090 240 l. 8.48 ft³
Water connection
MODEL
Inlet ow capacity per minute (Gallons / Liters)
INTERNATIONAL US
For the WF150, 185 4.23 / 16 5.28 / 20
For the WF235, 305, 400 7.93 + 13.2 / 30 + 50 7.93 + 13.2 / 30 + 50
Table 2
To comply with the WRAS water regulations: an 'approved' single check valve or
some other no less effective backow prevention device shall be tted at the point of
connection(s) between the supply and the tting (IRN R150).